B-FLAP - explosion isolation

B-Flap - Explosion Isolation flap valve

Effective solution for explosion isolation

The B-Flap check valve isolates explosions in dust collection system ducts, protecting adjacent equipment from dust explosion chain reactions.

Explosion protection with non-return valve

The B-Flap is a device that guarantees the isolation of an explosion in the ducts, protecting adjacent equipment from secondary explosions that can result from pressure and flame propagated through the ducts, ensuring the safety of the system.

To isolate an explosion:

  • Dust filters
  • Cyclones
  • Pneumatic transport
  • Dryers
  • Separators

Benefits:

  • Use for all types of dust, including metal
  • Certified for low value explosive dusts (MIE, MIT)
  • Installation in the direction and against the direction of flow
  • Horizontal and vertical installation
  • Can be installed after bends
  • Large range of models from DN 100 – 800
  • No power required
  • Low pressure loss
  • Possibility of installing a position sensor and a clogging sensor
  • Easy installation and maintenance
  • Mechanical locking after explosion
  • RPD mechanism with standard configuration
  • Optional in AISI 304 steel

B-Flap certification

2014/34/EU

NFPA 69

Operating principle of the B-Flap valve

explosion isolation, Обратный клапан B-Flap, изоляция взрыва, ізоляція вибуху, explosion isolation. методи ізоляції вибуху, ізоляція вибуху, вибухозахист, ДСТУ EN 15089, обмеження вибуху. методы изоляции взрыва, изоляция взрыва, взрывозащита, EN 15089, ограничение взрыва. explosion isolation methods, explosion isolation, explosion protection, EN 15089, explosion limitations.

During normal operation of the system, the damper inside the check valve is in the open position, allowing air and product to flow freely through the valve. In the event of an explosion, pressure and flame spread through the air ducts, reaching the check valve, the pressure wave closes the damper, which is fixed by the RPD mechanism and remains in the closed position. Thus, the check valve isolates the spread of explosion through the air ducts, preventing the risk of secondary explosions in adjacent equipment.

Installation options

The great advantage of the B-Flap check valve is its installation flexibility. You do not need to adjust the air duct system to install a check valve – install the valve as convenient for you.

Available B-Flap Diameters

ТипØA
(mm)
ØB
(mm)
ØC
(mm)
L
(mm)
N
(mm)
P
(mm)
Bес (кг)
DN 1001521321002802872449
DN 12517715712530530826911
DN 15020218215033033729413
DN 20025323320039038734418
DN 25030328325051050241741
DN 28034331728056053744748
DN 30036333730058055246751
DN 31537835231560056748254
DN 35541839235563060752262
DN 40046443840069565256873
DN 45051448845075070261988
DN 500564538500800752669101
DN 560664629560930838745157
DN 6307346986301005908815180
DN 71081477571011561102967305
DN 800904861800124611931057351