FLEX Flameless venting device
Explosion protection by flameless explosion venting
Benefits:
- Effective flame arresting and temperature reduction
- Creating a safe area for process equipment, buildings and personnel
- Suitable for the food and pharmaceutical industries
- High efficiency and reliability
- Easy to install
- Low installation costs
- Cost-effective solution
- 100% effective with flameless explosion pressure release
- Possibility of use for explosion protection of equipment working with light metal dust (Al, Mg, etc.)
- Certified for explosive dusts with very low values (MIE, MIT)
ΠΠ»Ρ Π²Π·ΡΡΠ²ΠΎΠ·Π°ΡΠΈΡΡ:
- Dust collectors
- Cyclones
- Bins/silos
- Dryers
- Mills
- Crushers
- Separators
- Any other industrial equipment
Equipment certification
Operating principle of Flex flameless explosion venting
- VMP Explosion venting panel
- Flame filter

During normal operation of the process equipment, the venting panel hermetically closes the ventilation hole, in the event of an explosion, a sharp pressure surge occurs inside the equipment, which, when reaching a value of 0.1 bar, ruptures the venting panel, releasing excess pressure and flame into the flame filter, which in turn reduces the temperature gases and effectively filter the flame by releasing warm air from the equipment. Thus, the flex protects process equipment and personnel in the event of an explosion.
- VIDEO
- PROTECTION PRINCIPLE
- MODELS REVIEW
Available models of Flex flameless venting device

Flex F
Used for explosion protection of equipment with a small internal volume.
- Specially designed for explosion protection of bucket elevators
- For equipment with low and medium operating pressure
- Built-in explosion sensor
- Stainless steel
- Integrated mounting flange
- Certification according to EN 14797, EN 16009

Flex R
Used for explosion protection of equipment with medium internal volume.
- For equipment with medium operating pressure
- Built-in explosion sensor
- Stainless steel
- Integrated mounting flange
- Certification according to EN 14797, EN 16009

Flex C
It is used for explosion protection of equipment with a large internal volume and equipment working with metal dust.
- Applicable for metal dust
- For equipment with high operating pressure
- Built-in explosion sensor
- Stainless steel
- Integrated mounting flange
- Certification according to EN 14797, EN 16009
Available sizes of Flex
- Flex F
- Flex R
- Flex C

| Π’ΠΈΠΏ | A (mm) | B (mm) | C (mm) | D (mm) | d – Π΄ΠΈΠ°ΠΌΠ΅ΡΡ ΠΎΡΠ²Π΅ΡΡΡΠΈΠΉΒ (ΠΌΠΌ) | n – ΠΊΠΎΠ»ΠΈΡΠ΅ΡΡΠ²ΠΎ Π±ΠΎΠ»ΡΠΎΠ² (ΡΡ.) | BΠ΅Ρ(ΠΊΠ³) | Π’ΠΈΠΏ VMP |
| FLEX F1 PRO | 225 | 675 | 265 | 465 | 14 | 20 | 24 | 150 x 600 |
| FLEX F2 PRO | 305 | 625 | 335 | 530 | 14 | 18 | 28 | 220 x 540 |
| FLEX F3 PRO | 390 | 710 | 420 | 620 | 14 | 18 | 35 | 630 x 310 |

| Π’ΠΈΠΏ | A (mm) | B (mm) | C (mm) | D (mm) | d – Π΄ΠΈΠ°ΠΌΠ΅ΡΡ ΠΎΡΠ²Π΅ΡΡΡΠΈΠΉΒ (ΠΌΠΌ) | n – ΠΊΠΎΠ»ΠΈΡΠ΅ΡΡΠ²ΠΎ Π±ΠΎΠ»ΡΠΎΠ² (ΡΡ.) | BΠ΅Ρ (ΠΊΠ³) | Π’ΠΈΠΏ VMP |
| FLEX R1 PRO | 390 | 710 | 635 | 410 | 14 | 18 | 40 | 630 x 310 |
| FLEX R2 PRO | 540 | 890 | 900 | 580 | 14 | 22 | 74 | 450 x 800 |
| FLEX R3 PRO | 666 | 1000 | 1130 | 735 | 14 | 34 | 109 | 586 x 920 |
| FLEX R4 PRO | 996 | 1198 | 1660 | 1070 | 14 | 42 | 215 | 915 x 1118 |

| Π’ΠΈΠΏ | A (mm) | B (mm) | C (mm) | D (mm) | E (mm) | F (mm) | G (mm) | d – Π΄ΠΈΠ°ΠΌΠ΅ΡΡ ΠΎΡΠ²Π΅ΡΡΡΠΈΠΉ Π΄Π»Ρ Π±ΠΎΠ»ΡΠΎΠ² (ΠΌΠΌ) | n – ΠΊΠΎΠ»ΠΈΡΠ΅ΡΡΠ²ΠΎ ΠΎΡΠ²Π΅ΡΡΡΠΈΠΉ Π΄Π»Ρ Π±ΠΎΠ»ΡΠΎΠ² (ΡΡ.) | BΠ΅Ρ (ΠΊΠ³) | Π’ΠΈΠΏ VMP |
| FLEX C1 PRO | 315 | 580 | 485 | 320 | 350 | 5 | 375 | 11 | 12 | 30 | DN 300 |
| FLEX C1 PRO S | 315 | 879 | 633 | 320 | 350 | 5 | 375 | 11 | 12 | 80 | DN 300 |
| FLEX C2 PRO S | 445 | 1075 | 633 | 450 | 486 | 5 | 525 | 13 | 12 | 87 | DN 450 |
| FLEX C3 PRO S | 505 | 1286 | 705 | 510 | 550 | 6 | 585 | 13 | 20 | 126 | DN 510 |
| FLEX C4 PRO S | 625 | 1385 | 1020 | 630 | 680 | 6 | 705 | 13 | 20 | 243 | DN 630 |
| FLEX C5 PRO | 815 | 2215 | 1020 | 820 | 860 | 6 | 895 | 13 | 24 | 291 | DN 800 |